ESNA1-LF2-LD

1302.ESNA1-LF2-LD

Download Data Sheet

Specified Performance
Permeate Flow: 12,000 gpd (45.4 m3/d)
CaCl2 Rejection: 91%
CaCl2 Rejection (Minimum/Maximum): 80%/96%
* Expected calcium rejection for a typical 500 ppm well water is 93% at 13 gfd operating flux and 25ºC.
Test Conditions: 500 ppm CaCl2 solution
75 psig (0.52 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 – 7.0 pH Range
Product Use and Restrictions
Maximum Applied Pressure: 600 psig (4.14 MPa)
Maximum Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 113 F (45 C)
pH Range, Continuous (Cleaning): 2-10 (1-12 at 25C for 30 minutes)
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater SDI (15 mins): 5.0
Maximum Feed Flow: 85 gpm (19.3 m3/h)
Minimum Brine Flow: 12 gpm (2.7 m3/h)
Maximum Pressure Drop for Each Element: 15 psi (0.10 MPa)

Request a quote