Specified Performance
Permeate Flow: 2,100 gpd (7.95 m3/d)
Salt Rejection: 99.7% (99.5% minimum)
Test Conditions: 1500 ppm NaCl solution
225 psig (1.55 MPa) Applied Pressure
77F (25C) Operating Temperature
15% Permeate Recovery
6.5 – 7.0 pH Range
Product Use and Restrictions
Maximum Applied Pressure: 600 psig (4.14 MPa)
Maximum Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 113F (45C)
pH Range, Continuous (Cleaning): 2-11 (1-13)
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater SDI (15 mins): 5.0
Maximum Feed Flow: 16 gpm (3.6 m3/h)
Minimum Brine Flow: 3 gpm (0.7 m3/h)
Maximum Pressure Drop for Each Element: 15 psi (0.10 MPa)