PRO-XT2

1302.PRO-XT2

Download Data Sheet

Specified Performance
Permeate Flow (at initial test): 6,230 gpd (23.6 m3/d)
Salt Rejection: 99.7% (99.6% minimum)
Test Conditions: 32,000 ppm NaCl solution
800 psig (5.5 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 – 7.0 pH Range
Product Use and Restrictions
Maximum Applied Pressure: Temperature dependent (see Chart 1 for detail)
Maximum Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: Pressure dependent (see Chart 1 for detail)
pH range, Continuous (Cleaning) 2-11 (1-13) at T <25˚C
2-11 (1-12) at T= 25 to 35˚C
3-10.5 (2-11) at T= 35 to 65˚C
4-8 (na) at T= 65 to 95˚C
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater SDI (15 mins): 5.0
Maximum Feed Flow: 75 gpm (17.0 m3/h)
Minimum Brine Flow: 12 gpm (2.7 m3/h)
Maximum Pressure Drop for Each Element: 10 psi (0.07 MPa)

Request a quote

Or send us an email to info@waterials.com

    Scroll to Top