Specified Performance
Permeate Flow: 12,000 gpd (45.4 m3/d)
Salt Rejection: 99.6% (99.5% minimum)
Test Conditions: 1500 ppm NaCl solution
150 psig (1.03 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 – 7.0 pH Range
Product Use and Restrictions
Maximum Applied Pressure: 600 psig (4.14 MPa)
Maximum Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 113 F (45 C)
pH Range, Continuous (Cleaning): 2-10.6 (1-12)
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater SDI (15 mins): 5.0
Maximum Feed Flow: 85 gpm (19.3 m3/h)
Minimum Brine Flow: 12 gpm (2.7 m3/h)
Maximum Pressure Drop for Each Element: 15 psi (0.10 MPa)